Skip to main content
LAYOUTCALCULATOR SCALE 1/16" CAD
2024 IRC Section R507 • SCALE: 1/16" FRACTIONAL
IRC R507.5 Beam Tables Framing & Carpentry

Deck Beam Span Calculator: Post Spacing & Footing Size (IRC)

Deck beam span and post spacing calculator built from 2024 IRC Tables R507.3.1, R507.4, R507.5 and R507.6: joist span & overhang, beam size, post height and footing size.

Calculation notes
Checked against: 2024 IRC Section R507
Published by LayoutCalculator. Confirm with your local building official.
REV DATE:
2024 IRC R507 Deck Beam Span, Post Spacing & Footing Size
Max post spacing (beam span)
9'-0"
3 posts at 8'-0" on center
Beam overhang max
2'-3"
Area per post
48 sq.ft
Footing (round / square)
18" dia / 16" sq
Footing thickness
6"

    Values from 2024 IRC Tables R507.3.1, R507.4, R507.5(1)–(4) and R507.6. Post count assumes posts at both beam ends; area per post is post spacing × (joist span ÷ 2 + overhang). Confirm with your local building department.

    All beam sizes for this joist span (selected species & load)

    Beam1-ply2-ply3-ply

    Pre-Calculated Deck Beam Span Calculator Blueprints (0 Field Specs)

    Select any standard jobsite specification below to load its exact 2D SVG diagram and engineering tables:

    Contractor & Instructor Widget

    Embed This 2D SVG Instrument on Your Website (Ad-Free)

    Carpentry instructors, trade schools, and builders can embed the standalone ad-free version of this 2D CAD calculator with one HTML snippet.

    Official Building Code & Industry Standard Citations

    • ICC International Residential Code (IRC R311, R312, R403, R602, R802) Stairways, 4" guardrail spheres, frost-line footings, stud framing, and rafter birdsmouths. Reference: ICC Digital Codes (codes.iccsafe.org).
    • NFPA 70 / National Electrical Code (NEC Article 690) Solar PV cold-temperature Voc correction (690.7) and 156% OCPD sizing (690.8). Reference: National Fire Protection Association (nfpa.org).
    • ACI 318 Concrete & TCNA / ANSI A108.02 Standards Structural concrete footings, rebar cover, symmetrical tile layout centering, and EJ171 joints. Reference: ACI (concrete.org) & TCNA (tcnatile.com).
    • AWI Woodwork, APA Engineered Wood & AWC NDS Finish millwork tolerances, panel kerf allowances, and wood span design values. Reference: AWI (awinet.org) & AWC (awc.org).

    How the 2024 IRC R507 Deck Beam, Post and Footing Tables Work

    How do you size a deck beam and space the posts?

    Start from the joists: check the joist span and any overhang against Table R507.6. Then look up the beam in Tables R507.5(1)–(4) using that joist span and overhang; the result is the maximum distance between posts. Divide the beam length by that span to get the post count, multiply post spacing by (joist span ÷ 2 + overhang) to get the deck area each post carries, and use that area to check post height in Table R507.4 and footing size in Table R507.3.1.

    1. The Four Steps

    1. Joist check: joist span ≤ Table R507.6 span; overhang ≤ Table R507.6 cantilever for that back span
    2. Beam span (post spacing) = Table R507.5 value for (joist span, joist overhang)
    3. Posts = ceil(beam length ÷ beam span) + 1; beam overhang past end post ≤ beam span ÷ 4
    4. Area per post = post spacing × (joist span ÷ 2 + joist overhang) → Table R507.4 post height, Table R507.3.1 footing

    2. Deck Beam Span Chart: Southern Pine, 40 psf, No Joist Overhang

    Maximum deck beam span by joist span, 2024 IRC Table R507.5(1), Southern pine
    Beam6 ft joists8 ft joists10 ft joists12 ft joists14 ft joists16 ft joists18 ft joists
    2-ply 2x89'-4"8'-9"8'-2"7'-7"6'-9"6'-5"6'-2"
    2-ply 2x1011'-0"10'-4"9'-8"9'-0"8'-0"7'-8"7'-4"
    2-ply 2x1213'-0"12'-2"11'-4"10'-7"9'-5"9'-0"8'-7"
    3-ply 2x811'-7"10'-11"10'-3"9'-6"8'-6"8'-1"7'-9"
    3-ply 2x1013'-11"13'-0"12'-1"11'-2"10'-0"9'-7"9'-2"
    3-ply 2x1216'-3"15'-3"14'-3"13'-3"11'-10"11'-3"10'-9"

    Source: 2024 IRC Table R507.5(1), No. 2 grade, wet service factor included, 10 psf dead load, L/360 main span. Other species and the 50/60/70 psf ground snow tables are built into the calculator above.

    3. Worked Example: 12 ft × 16 ft Attached Deck

    Southern pine 2x10 joists at 16" OC span 12 ft from the ledger to a dropped beam (Table R507.6 allows 14 ft 0 in). A 2-ply 2x10 beam may span 9 ft 0 in, so a 16 ft beam needs 3 posts at 8 ft on center. Each interior post carries 8 × 6 = 48 sq.ft. A 6x6 Southern pine post is allowed 14 ft tall at that area, and on 1,500 psf soil Table R507.3.1 calls for an 18 in round (16 in square) footing at least 6 in thick, interpolating between the 40 and 60 sq.ft rows.

    4. Details Inspectors Check

    • Built-up beam plies are fastened with two rows of 10d (3" × 0.128") nails at 16" on center along each edge (R507.5), and plies must be continuous between bearing points (R507.5.1).
    • Beam ends need at least 1-1/2" of bearing on wood or metal and 3" on concrete or masonry (R507.5.1).
    • Beam-to-post connections follow Figures R507.5.2(1) and (2) or a manufactured connector sized for the post and beam; bolts need washers under the head and nut.
    • Footings sit at least 12" below undisturbed ground (R507.3.2) and below the frost line for decks attached to a frost-protected house (R507.3.3).

    Field Manuals & Code Tables for Deck Beam Span Calculator

    Index of All 107 Manuals →

    Frequently Asked Questions (Deck Beam Span Calculator)

    How far apart can deck posts be with a 2-ply 2x10 beam?

    ▼

    Under 2024 IRC Table R507.5(1) (40 psf live load, No. 2 lumber), a 2-ply 2x10 Southern pine beam supporting 12 ft joists with no overhang can span 9 ft 0 in between posts. In Douglas fir-larch, hem-fir or SPF the limit is 8 ft 7 in. Shorter joists allow longer beam spans: with 8 ft joists the same Southern pine beam spans 10 ft 4 in.

    What size beam do I need for a 12 ft joist span and 8 ft post spacing?

    ▼

    For Southern pine at 40 psf, a 2-ply 2x10 (9 ft 0 in) or 2-ply 2x12 (10 ft 7 in) works, while a 2-ply 2x8 (7 ft 7 in) does not. For DF/HF/SPF a 2-ply 2x10 allows 8 ft 7 in, so it also works. Snow loads of 50–70 psf shorten every span; pick the load in the calculator.

    Does a joist overhang change the allowed beam span?

    ▼

    Yes. The 2024 IRC beam tables list joist span and cantilever pairs. With 12 ft joists that overhang the beam by 2 ft, a 2-ply 2x10 Southern pine beam drops from 9 ft 0 in to 7 ft 8 in. Interpolation is only permitted when the joists have no cantilever, so the calculator rounds up to the next tabulated pair.

    How far can a deck beam cantilever past the post?

    ▼

    IRC R507.5.1 allows a beam to cantilever beyond its bearing up to one-fourth of the actual adjacent beam span. A beam with posts 8 ft apart can overhang the end post by up to 2 ft.

    How tall can a 4x4 or 6x6 deck post be?

    ▼

    Table R507.4 limits post height (top of footing to underside of beam) by the deck area each post carries. At 40 psf a Southern pine 4x4 may be 14 ft 0 in at 20 sq.ft, 11 ft 0 in at 60 sq.ft and 8 ft 4 in at 100 sq.ft. A Southern pine 6x6 is allowed 14 ft 0 in up to the 160 sq.ft limit of the table.

    What size concrete footing does a deck post need?

    ▼

    Table R507.3.1 sizes footings by tributary area, load and soil bearing value. At 40 psf on 1,500 psf soil, a post carrying 40 sq.ft needs a 16 in round (14 in square) footing 6 in thick; at 80 sq.ft it needs a 22 in round (20 in square) footing 7 in thick. Footings must also be at least 12 in below undisturbed ground and below the frost line where the deck is attached to a frost-protected house.