Skip to main content
LAYOUTCALCULATOR SCALE 1/16" CAD
2024 IRC Section R602.7 • SCALE: 1/16" FRACTIONAL
IRC R602.7(1) Headers Framing & Carpentry

Header Size Calculator: Header Span Chart for Doors & Windows (IRC)

Header size calculator from 2024 IRC Table R602.7(1): max header span and jack studs for exterior bearing walls by load, snow, building width and bracing.

Calculation notes
Checked against: 2024 IRC Section R602.7
Published by LayoutCalculator. Confirm with your local building official.
REV DATE:
2024 IRC R602.7(1) Exterior Wall Header Span & Jack Studs
Maximum allowable span
—

Span table for the selected settings

Pre-Calculated Header Size Calculator Blueprints (0 Field Specs)

Select any standard jobsite specification below to load its exact 2D SVG diagram and engineering tables:

Contractor & Instructor Widget

Embed This 2D SVG Instrument on Your Website (Ad-Free)

Carpentry instructors, trade schools, and builders can embed the standalone ad-free version of this 2D CAD calculator with one HTML snippet.

How to Read the IRC Header Span Table

IRC Table R602.7(1) sizes headers and girders in exterior bearing walls by what they carry (roof and ceiling, plus one or two floors), the ground snow load, and the building width measured perpendicular to the ridge. Each cell gives the maximum span and the number of jack studs required at each end.

For a 24 ft wide house with 30 psf or less ground snow, a header carrying only the roof and ceiling can be 2-2x10 up to 6 ft 10 in with two jack studs per end, or 2-2x12 up to 8 ft 1 in. Widths between 12, 24 and 36 ft may be interpolated.

The spans assume the top of the header is braced by perpendicular framing. When cripple studs bear on the header instead, footnote f reduces 2x8, 2x10 and 2x12 header spans to 70%. Interior bearing-wall headers use Table R602.7(2).

Header Span Chart: Exterior Wall Supporting Roof & Ceiling Only

Header Span Chart: Exterior Wall Supporting Roof & Ceiling Only
Header12 ft wide24 ft wide36 ft wide
2-ply 2x44'-0" (1J)3'-1" (1J)2'-7" (1J)
2-ply 2x66'-0" (1J)4'-7" (1J)3'-10" (1J)
2-ply 2x87'-7" (1J)5'-9" (1J)4'-10" (2J)
2-ply 2x109'-0" (1J)6'-10" (2J)5'-9" (2J)
2-ply 2x1210'-7" (2J)8'-1" (2J)6'-10" (2J)
3-ply 2x89'-5" (1J)7'-3" (1J)6'-1" (1J)
3-ply 2x1011'-3" (1J)8'-7" (1J)7'-3" (2J)
3-ply 2x1213'-2" (1J)10'-1" (2J)8'-6" (2J)
4-ply 2x810'-11" (1J)8'-4" (1J)7'-0" (1J)
4-ply 2x1012'-11" (1J)9'-11" (1J)8'-4" (1J)
4-ply 2x1215'-3" (1J)11'-8" (1J)9'-10" (2J)
1-ply 2x64'-0" (1J)3'-1" (2J)2'-7" (2J)
1-ply 2x85'-1" (2J)3'-11" (2J)3'-3" (2J)
1-ply 2x106'-0" (2J)4'-8" (2J)3'-11" (2J)
1-ply 2x127'-1" (2J)5'-5" (2J)4'-7" (3J)

Source: 2024 IRC Table R602.7(1), 30 psf ground snow. Values transcribed from the published table; confirm local amendments with your building department.

Field Manuals & Code Tables for Header Size Calculator

Index of All 107 Manuals →

Frequently Asked Questions (Header Size Calculator)

What size header do I need for a 6 ft opening?

▼

For an exterior wall carrying only roof and ceiling on a 24 ft wide house with 30 psf or less ground snow, IRC Table R602.7(1) allows a 2-2x10 header up to 6 ft 10 in with two jack studs per end. A 2-2x8 (5 ft 9 in) is too short.

How far can a double 2x12 header span?

▼

A 2-2x12 header carrying roof and ceiling spans 8 ft 1 in on a 24 ft wide house and 6 ft 10 in on a 36 ft wide house at 30 psf ground snow. If it also carries one center-bearing floor, the 24 ft-wide span drops to 6 ft 8 in.

How many jack studs does a header need?

▼

Table R602.7(1) lists the number of jack studs at each end next to every span. Most 2-ply headers need one or two; larger spans and heavier loads need up to four. Where one jack stud is required, an approved framing anchor may replace it.

What is the header size for a 2x6 wall?

▼

Table R602.7(1) sizes headers by load, not wall thickness; a 2x6 wall just needs a header assembly about 5-1/2" wide, such as a 3-ply header or a 2-ply header with a spacer. Check the span for the ply count you build.

Does snow load change header size?

▼

Yes. A 2-2x10 header carrying roof and ceiling on a 24 ft wide house spans 6 ft 10 in at 30 psf ground snow but 5 ft 11 in at 50 psf.