Need an Instant Scale Blueprint? Launch Board & Batten Spacing
Generate real-time 1/16" fractional dimensions, framing square marks, and printable workshop sheets.
What Is the Standard Rule for Door & Window Casing Reveal?
AWI AWS Section 6-300 — Standing & Running Trim Jamb Reveals & Miters: Never install door or window casing dead-flush (0" reveal) with the inside jamb face: hinge barrels bind against flush trim, seasonal wood movement cracks paint seams, and 1/32" slip looks crooked. Use a crisp 3/16-inch (0.1875") reveal on standard 2-1/4" to 2-3/4" residential casing and a bolder 1/4-inch (0.250") reveal on 3-1/2"+ wide casing or heavy commercial/historic jambs.
Interactive Jobsite Verification Instrument
Key Engineering & Code Takeaways
- Never install door or window casing dead-flush (0" reveal) with the inside jamb face: hinge barrels bind against flush trim, seasonal wood movement cracks paint seams, and 1/32" slip looks crooked.
- Use a crisp 3/16-inch (0.1875") reveal on standard 2-1/4" to 2-3/4" residential casing and a bolder 1/4-inch (0.250") reveal on 3-1/2"+ wide casing or heavy commercial/historic jambs.
- For mitered casing, Inside Short-Point Leg Length = Jamb Opening Height + Reveal, and Inside Short-Point Head Length = Jamb Opening Width + (2 x Reveal).
- For square Craftsman flat-stock headers, cut 1x6 head casing to Jamb Width + (2 x Reveal) + (2 x Leg Width) + (2 x Ear Overhang, typically 1/2" per side = +1.00" total).
Part of our Finish Carpentry & Trim series; start with Board and Batten Spacing Formula. Related: MDF vs. Solid Poplar vs. PVC Trim for Board and Batten Walls, How to Handle Outlets & Switches in Board and Batten Layouts, How to Nail, Caulk & Paint Board & Batten Without Cracks.
Exact Casing Cut-List Reference for Standard 36" x 80" Door (36.00" x 80.50" Inside Jamb)
| Casing Architecture & Stock | Jamb Reveal | Leg Inside / Square Length | Head Inside Short Point | Head Overall Long Point / Cut |
|---|---|---|---|---|
| 2-1/4" WM 356 Colonial (Mitered) | 3/16" (0.1875") | 80-11/16" short pt | 36-3/8" (36.375") | 40-7/8" (40.875" long pt) |
| 2-1/4" WM 356 Colonial (Mitered) | 1/4" (0.2500") | 80-3/4" short pt | 36-1/2" (36.500") | 41-0" (41.000" long pt) |
| 3-1/4" WM 445 Colonial (Mitered) | 3/16" (0.1875") | 80-11/16" short pt | 36-3/8" (36.375") | 42-7/8" (42.875" long pt) |
| 3-1/2" 1x4 Modern Mitered Flat | 1/4" (0.2500") | 80-3/4" short pt | 36-1/2" (36.500") | 43-1/2" (43.500" long pt) |
| Craftsman: 1x4 Legs + Flush 1x6 Head | 3/16" (0.1875") | 80-11/16" square cut | 43-3/8" outer leg span | 43-3/8" (0" ear overhang) |
| Craftsman: 1x4 Legs + 1/2" Ears 1x6 | 3/16" (0.1875") | 80-11/16" square cut | 43-3/8" outer leg span | 44-3/8" (+1/2" ear each side) |
| Craftsman w/ 1/2" Fillet + 1x6 Head | 1/4" (0.2500") | 80-3/4" to fillet btm | 43-1/2" outer leg span | 44-1/2" head / 45-0" fillet |
1. Why Master Carpenters Scribe 3/16" or 1/4" Jamb Reveals Instead of Flush Trim
Step-back jamb reveal—setting the inner edge of door and window casing back 3/16 inch or 1/4 inch from the inside face of the jamb—solves three structural finish-carpentry headaches simultaneously. First, residential butt-hinge barrels protrude across the inside edge of the hinge jamb; setting casing flush pinches against the hinge knuckles and prevents the removable hinge pin from lifting straight upward! Second, wood door jambs rarely sit planar to adjacent 1/2" drywall to within 0.005"; stepping back onto the solid 11/16" jamb edge gives glue and 18-gauge brads a clean wood-to-wood registration ledge.
Third, human vision detects a 1/32" misalignment across a supposedly flush seam from 15 feet away, whereas a deliberate 3/16" (0.1875") shadow reveal absorbs minor wood movement invisibly. Choose 3/16" on delicate 2-1/4" to 2-3/4" profiles (so at least 1/2" of solid jamb edge remains glued underneath the casing), and step up to 1/4" on bold 3-1/2" Craftsman casing or out-of-square remodel jambs.
2. Worked Cut-List Math: Mitered Casing vs 3-Piece Built-Up Craftsman Headers
When coordinating door and window casing widths alongside adjacent wall paneling in the Board and Batten Wall Spacing Calculator, scribe all three jamb sides first with a machined aluminum 3/16" / 1/4" combination trim gauge rather than trusting a tape measure:
- Mitered Casing Formula (36.00" × 80.50" Jamb, 3/16" Reveal): Mark your pencil ticks at the intersection of the left, right, and head reveal lines! Because both side reveals add to the top span,
Head Inside Short Point = 36.00" + (2 × 0.1875") = 36.375" (36-3/8"), while each vertical leg measures80.50" + 0.1875" = 80.6875" (80-11/16")from finished flooring to inside miter point. - Craftsman Flat-Stock Header Formula (1x4 [3.50"] Legs + 1x6 [5.50"] Head): Cut both vertical
1x4legs square at80-11/16". Measure total span across the outside edges of installed legs:36.00" + 0.375" reveals + (2 × 3.50" legs) = 43.375" (43-3/8"). - Adding Classical Ear Overhangs & Parting Bead: Overhanging a plain
1x6header by 1/2" (0.50") past each vertical leg yields43.375" + 1.00" = 44.375" (44-3/8"). If adding a1/2" × 1-1/8"bullnose parting bead underneath the1x6and a3/4" × 1-1/4"cap mold on top, overhang the parting bead3/4"per side (44-7/8") and the top cap1"per side (45-3/8") with tiny mitered self-returns!
3. Eliminating Proud-Drywall "Open Heel" Miters with Relief Planing & Biscuits
Nothing frustrates trim carpenters faster than cutting two dead-accurate 45.0-degree miters only to watch the inside point touch while the outer heel gaps open 1/16" as soon as the casing is nailed against the wall! That gap happens whenever taped drywall around the rough opening stands 1/16" to 1/8" prouder than the 4-9/16" wood door jamb—tilting both casings backward toward the wall and prying the outside miter heels apart.
Test-bridge a 6" straightedge across every jamb-to-drywall seam before cutting trim. If drywall bulges proud of the wood jamb, score the unpainted drywall paper hidden behind the casing footprint and tap the high gypsum edge down gently with a hammer poll—or bevel-plane 1/16" off the outer rear relief channel of your casing legs! Finally, pre-assemble the left leg, right leg, and header flat on the floor using clam clamps, PVA glue, or #0 biscuits / pocket screws on the back of wide 3-1/2" stock, and lift the entire 3-sided frame onto the jamb as one monolithic unit.
Primary Standards & Building Code Authorities (AWI AWS Section 6-300 — Standing & Running Trim Jamb Reveals & Miters)
All dimensions, tolerances, and safety thresholds in this field guide are cross-referenced against current US residential building, electrical, and trade standards:
- ICC International Residential Code (IRC R311.7) Stairway rise/run geometry, headroom, and handrail code requirements. ICC Digital Codes →
- NFPA 70 / National Electrical Code (NEC 690) Photovoltaic Voc temperature coefficients, ampacity, and OCPD sizing. NFPA Standards →
- TCNA Handbook & ANSI A108.02 Ceramic and porcelain tile centering, lippage, and EJ171 expansion joints. TCNA Council →
- APA Engineered Wood & AWC NDS Structural wood panel sizing, kerf allowances, and framing lumber spans. APA Wood →
Pre-Calculated Blueprints for Board & Batten Spacing (12 Specs)
Related Calculators & Finish Carpentry & Trim Hub
Frequently Asked Questions: AWI AWS Section 6-300 — Standing & Running Trim Jamb Reveals & Miters
How do I set window stool ("sill") horn overhangs so casing lands cleanly on top?
▼
Extend your horizontal window stool ears past the outer edge of the side window casings by the exact same overhang used on your Craftsman headers (or by the thickness of the window stool—typically 3/4" to 1-1/8" past the outer edge of mitered colonial casing!). For 2-1/4" casing with a 3/16" reveal and 1" ear overhang, cut the stool length to Inside Jamb Width + 2*(0.1875" + 2.25" + 1.00") = Jamb + 6-7/8".
What do I do when a door jamb sits 1/8 inch PROUD of the drywall instead of recessed?
▼
When a 4-9/16" prehung jamb projects 1/8" proud of older 3/8" drywall or un-furred framing, casing rocks inward and opens at the inside miter toe! Rip tapered wood shims behind the outer edge of the casing along the drywall, or rabbet 1/8" off the inner 9/16" jamb contact strip on the table saw so the casing sits dead-flat across both planes.
How close to a perpendicular wall can door casing fit when framing a tight closet corner?
▼
A standard 4-1/2" rough stud jack + cripple corner leaves ~3-1/2" to 4" from inside jamb to corner drywall—ample room for 2-1/4" casing plus a 3/16" reveal. Whenever a tight hallway forces you to rip one casing leg narrower against an adjacent wall, scribe that leg cleanly to the wall while keeping the 3/16" jamb reveal untouched so the header miter still matches cleanly.