Skip to main content
LAYOUTCALCULATOR SCALE 1/16" CAD
2024 IRC R403 & ACI 318 • SCALE: 1/16" FRACTIONAL
ACI 318 / IRC R403 Pier Concrete & Foundations

10" × 36" Deck Pier — 10" × 36" Deck Pier Sonotube: 80lb & 60lb Bag Count

Concrete volume and bag calculator for six 10-inch by 36-inch Sonotube deck footings: 1.64 cu ft per pier, 18 bags of 80-lb mix, and water gallons.

Calculation notes
Checked against: 2024 IRC R403 & ACI 318
Published by LayoutCalculator. Confirm with your local building official.
REV DATE:
Result summary

One 10" × 36" pier requires 1.64 cu ft net (~3 bags of 80-lb concrete). Six piers plus 10% waste total 10.80 cu ft (18 × 80-lb bags or 24 × 60-lb bags) with 1,091 lbs soil capacity per pier.

Typical Field Application

Low-elevation backyard patio decks, boardwalks, and AC condenser equipment pads in 30-inch frost zones.

Field note

Consolidate each 12-inch lift of concrete inside narrow 10-inch tubes using a scrap length of #4 rebar to eliminate honeycombing air pockets around J-bolt anchors.

IRC R403.1 & ACI 318 2D SVG Concrete Sonotube & Footing Pier Console
80-lb Bags 18 Bags
Volume 0.40 yd³
Pier Load 1,091 lb
10" Ø Tube
8" (Fence) 12" (Deck) 18" (Porch) 36" (Caisson)
36" (3.0 ft)
18" (South) 42" (36" Frost) 54" (48" Frost) 96"
6 Piers
✓ IRC R403.1 FOOTING BEARING VERIFIED 1,091 lb/pier

Each pier supports 1,091 lbs allowable axial load (6,546 lbs across 6 piers). Hand/mixer batch: 18 × 80-lb bags (13.5 gal water).

2D IRC R403.1 Concrete Sonotube Pier, Frost Line, Rebar & Bearing Blueprint Interactive scale CAD cross-section of a cylindrical concrete Sonotube pier showing grade horizon, winter frost line, 6-inch above-grade projection, #4 rebar cage, ABU66Z post standoff base, and soil bearing capacity. FINISH GRADE HORIZON (0.0") WINTER FROST DEPTH LINE (-30") ABU66Z POST BASE + 1/2" J-BOLT (+6" DRY) ↑ ↑ ↑ ALLOWABLE BEARING: 1,091 LBS/PIER @ 2,000 PSF ↑ ↑ ↑ Total: 36" 6 PIERS (10" Ø) | 80-LB BAGS: 18 (0.40 YD³) Single Pier: 1.64 ft³ • Gross w/ 10% Waste: 10.8 ft³
80-lb Mix Bags
18 Bags
Add ~13.5 gal Water
60-lb / 50-lb
24 / 29
60lb / 50lb Bags
Cubic Yards
0.40 yd³
10.8 ft³ Gross
Per-Pier Volume
1.64 ft³
2.7 × 80lb / pier
Max Pier Load
1,091 lb
0.55 ft² Footprint

Concrete Volume, Bag Yield & Bearing Table Bag-Mix Friendly

Calculated per ASTM C387 / Quikrete commercial bag yields (0.60 ft³ per 80-lb bag) and 2024 IRC Table R401.4.1 soil bearing values:

Concrete Sonotube Volume, Bag Counts, Water Ratio, and Soil Bearing Schedule
Engineering Metric Calculated Quantity Jobsite Mix / Code Spec
Single Pier Net Volume 1.64 cu ft 0.061 cu yd net
Gross Batch (+10% Waste) 10.80 cu ft 0.40 cubic yards (6 piers)
80-lb Concrete Bags (0.60 ft³) 18 Bags 0.4 pallets • 13.5 gal mix water
60-lb Concrete Bags (0.45 ft³) 24 Bags 1,440 lbs total dry weight
50-lb Fast-Setting Bags (0.375 ft³) 29 Bags Rapid post/light pier option
Allowable Axial Load / Pier 1,091 lbs 0.55 sq ft @ 2,000 PSF

Required Bill of Materials (BOM) & Hardware

Auto-Calculated Quantities
  • 18 × 80-lb Bags 4,000 PSI Air-Entrained Concrete Mix (or 24 × 60-lb) 0.40 yd³ gross batch including +10% excavation waste
  • 6 × 10" Ø Wax-Lined Cardboard Concrete Pier Forms Cut to 36" height per pier (+6" above finish grade)
  • 6 × Simpson Strong-Tie ABU66Z Standoff Post Bases & 1/2"×8" HDG J-Bolts Plus 12 × #4 (1/2") Deformed Steel Rebar Dowels (maintain 3" bottom concrete cover)

Independent Field Spec Notice: Footing volumes, soil capacities, and 3-inch earth-cast rebar cover follow 2024 IRC R403.1, Table R401.4.1, and ACI 318. Confirm local winter frost depth with your municipal building department.

Need full-scale Pier Excavation & Batch Sheet + Vector .SVG file?

Pre-Calculated Sonotube Footing Calculator Blueprints (12 Field Specs)

Select any standard jobsite specification below to load its exact 2D SVG diagram and engineering tables:

Open Base Sonotube Footing Calculator →
Contractor & Instructor Widget

Embed This 2D SVG Instrument on Your Website (Ad-Free)

Carpentry instructors, trade schools, and builders can embed the standalone ad-free version of this 2D CAD calculator with one HTML snippet.

SPECIFICATION WALKTHROUGH // 10" × 36" Deck Pier

Mathematical Derivation & Field Specifications: 10" × 36" Deck Pier

Updated • Published by LayoutCalculator

Pouring 6 concrete footings with a 10" shaft diameter and 36" total depth (cylindrical straight shaft) requires 1.64 cu.ft net volume per pier. Including a 10% earth-auger and spillage allowance yields 10.80 cu.ft (0.40 cubic yards) total concrete.

Order 18 bags of 80-lb pre-blended concrete (0.60 cu.ft/bag), 24 bags of 60-lb mix (0.45 cu.ft/bag), or 29 bags of 50-lb mix, hydrated with approximately 13.5 gallons of clean water. Resting on 2,000 PSF soil per 2024 IRC Table R401.4.1, each pier's 0.55 sq.ft footprint supports up to 1,091 lbs.

Tube Diameter Volume & Soil Bearing Comparison (6 Piers @ 36" Depth)

Tube Size Net / Pier Gross Total (+10%) 80-Lb Bags 60-Lb Bags Soil Bearing / Pier
8" Tube 1.05 ft³ 6.91 ft³ 12 Bags 16 Bags 698 lbs
10" Tube (Selected) 1.64 ft³ 10.80 ft³ 18 Bags 24 Bags 1,091 lbs
12" Tube 2.36 ft³ 15.55 ft³ 26 Bags 35 Bags 1,571 lbs
16" Tube 4.19 ft³ 27.65 ft³ 47 Bags 62 Bags 2,793 lbs
20" Tube 6.54 ft³ 43.20 ft³ 72 Bags 96 Bags 4,363 lbs

Pier Excavation, Rebar Cage & Pour Lift Schedule (36" Total Pier Height)

Elevation Zone Target Dimension ACI 318 / IRC R403 Field Requirement
1. Subgrade Base 30" Below Grade 6"+ below local frost depth on undisturbed native soil
2. Rebar Clear Cover 3" Bottom / 2" Side Suspend #4 vertical bars on plastic chairs (never driven into dirt)
3. Above-Grade Plinth +6" Splash Reveal Wet-set 1/2" or 5/8" HDG J-bolt w/ 7" embedment for Simpson ABU base

Official Building Code & Industry Standard Citations

  • ICC International Residential Code (IRC R403.1) Sets minimum footing sizes by load and presumptive soil bearing capacity, and requires footings to bear below the local frost line. Reference: ICC Digital Codes (codes.iccsafe.org).

Field Manuals & Code Tables for Sonotube Footing Calculator

Index of All 107 Manuals →

Frequently Asked Questions (10" × 36" Deck Pier)

How many 80-lb and 60-lb bags of concrete do 6 piers of 10" × 36" require?

▼

Each 10" × 36" cylindrical pier holds 1.64 cu.ft net. For 6 piers with 10% waste (10.80 cu.ft / 0.40 cu.yd), purchase 18 bags of 80-lb mix (or 24 bags of 60-lb mix) and ~13.5 gallons of clean water.

How much vertical load can one 10" Sonotube footing support at 2000 PSF?

▼

With a bottom bearing footprint of 0.55 sq.ft resting on undisturbed 2,000 PSF soil per IRC Table R401.4.1, each pier supports up to 1,091 lbs of allowable tributary dead-plus-live load.

Should I mix bagged concrete or order a ready-mix truck for 10.8 cu.ft (0.40 yd³)?

▼

At 0.40 cubic yards (18 × 80-lb bags), mixing 4,000 PSI bagged concrete on-site in a 3.5–5.0 cu.ft drum mixer avoids ready-mix short-load delivery fees.