Skip to main content
LAYOUTCALCULATOR SCALE 1/16" CAD
2024 IRC R403 & ACI 318 • SCALE: 1/16" FRACTIONAL
ACI 318 / IRC R403 Pier Concrete & Foundations

10" × 42" Frost Pier (8x) — 10" × 42" Sonotube Concrete Bags (8 Deck Footings)

Exact 80-lb and 60-lb concrete bag count for eight 10-inch by 42-inch Sonotube deck piers: 1.91 cu ft per tube, 28 bags of 80-lb mix, and soil load.

Calculation notes
Checked against: 2024 IRC R403 & ACI 318
Published by LayoutCalculator. Confirm with your local building official.
REV DATE:
Result summary

Each 10" × 42" tube holds 1.91 cu ft net (3.18 × 80-lb bags). Eight piers with 10% waste total 16.80 cu ft (0.62 cu yd), requiring 28 bags of 80-lb mix (or 38 × 60-lb bags) at 1,091 lbs bearing/pier.

Typical Field Application

Midwest and Northeast 36-inch frost-line ledger-free floating decks with 8 perimeter and interior piers.

Field note

String tight mason lines across batter boards before setting 8 tubes so every post base lands within 1/4" of your beam layout centers.

IRC R403.1 & ACI 318 2D SVG Concrete Sonotube & Footing Pier Console
80-lb Bags 28 Bags
Volume 0.62 yd³
Pier Load 1,091 lb
10" Ø Tube
8" (Fence) 12" (Deck) 18" (Porch) 36" (Caisson)
42" (3.5 ft)
18" (South) 42" (36" Frost) 54" (48" Frost) 96"
8 Piers
✓ IRC R403.1 FOOTING BEARING VERIFIED 1,091 lb/pier

Each pier supports 1,091 lbs allowable axial load (8,728 lbs across 8 piers). Hand/mixer batch: 28 × 80-lb bags (21 gal water).

2D IRC R403.1 Concrete Sonotube Pier, Frost Line, Rebar & Bearing Blueprint Interactive scale CAD cross-section of a cylindrical concrete Sonotube pier showing grade horizon, winter frost line, 6-inch above-grade projection, #4 rebar cage, ABU66Z post standoff base, and soil bearing capacity. FINISH GRADE HORIZON (0.0") WINTER FROST DEPTH LINE (-36") ABU66Z POST BASE + 1/2" J-BOLT (+6" DRY) ↑ ↑ ↑ ALLOWABLE BEARING: 1,091 LBS/PIER @ 2,000 PSF ↑ ↑ ↑ Total: 42" 8 PIERS (10" Ø) | 80-LB BAGS: 28 (0.62 YD³) Single Pier: 1.91 ft³ • Gross w/ 10% Waste: 16.8 ft³
80-lb Mix Bags
28 Bags
Add ~21 gal Water
60-lb / 50-lb
38 / 45
60lb / 50lb Bags
Cubic Yards
0.62 yd³
16.8 ft³ Gross
Per-Pier Volume
1.91 ft³
3.2 × 80lb / pier
Max Pier Load
1,091 lb
0.55 ft² Footprint

Concrete Volume, Bag Yield & Bearing Table Bag-Mix Friendly

Calculated per ASTM C387 / Quikrete commercial bag yields (0.60 ft³ per 80-lb bag) and 2024 IRC Table R401.4.1 soil bearing values:

Concrete Sonotube Volume, Bag Counts, Water Ratio, and Soil Bearing Schedule
Engineering Metric Calculated Quantity Jobsite Mix / Code Spec
Single Pier Net Volume 1.91 cu ft 0.071 cu yd net
Gross Batch (+10% Waste) 16.80 cu ft 0.62 cubic yards (8 piers)
80-lb Concrete Bags (0.60 ft³) 28 Bags 0.7 pallets • 21 gal mix water
60-lb Concrete Bags (0.45 ft³) 38 Bags 2,280 lbs total dry weight
50-lb Fast-Setting Bags (0.375 ft³) 45 Bags Rapid post/light pier option
Allowable Axial Load / Pier 1,091 lbs 0.55 sq ft @ 2,000 PSF

Required Bill of Materials (BOM) & Hardware

Auto-Calculated Quantities
  • 28 × 80-lb Bags 4,000 PSI Air-Entrained Concrete Mix (or 38 × 60-lb) 0.62 yd³ gross batch including +10% excavation waste
  • 8 × 10" Ø Wax-Lined Cardboard Concrete Pier Forms Cut to 42" height per pier (+6" above finish grade)
  • 8 × Simpson Strong-Tie ABU66Z Standoff Post Bases & 1/2"×8" HDG J-Bolts Plus 16 × #4 (1/2") Deformed Steel Rebar Dowels (maintain 3" bottom concrete cover)

Independent Field Spec Notice: Footing volumes, soil capacities, and 3-inch earth-cast rebar cover follow 2024 IRC R403.1, Table R401.4.1, and ACI 318. Confirm local winter frost depth with your municipal building department.

Need full-scale Pier Excavation & Batch Sheet + Vector .SVG file?

Pre-Calculated Sonotube Footing Calculator Blueprints (12 Field Specs)

Select any standard jobsite specification below to load its exact 2D SVG diagram and engineering tables:

Open Base Sonotube Footing Calculator →
Contractor & Instructor Widget

Embed This 2D SVG Instrument on Your Website (Ad-Free)

Carpentry instructors, trade schools, and builders can embed the standalone ad-free version of this 2D CAD calculator with one HTML snippet.

SPECIFICATION WALKTHROUGH // 10" × 42" Frost Pier (8x)

Mathematical Derivation & Field Specifications: 10" × 42" Frost Pier (8x)

Updated • Published by LayoutCalculator

Pouring 8 concrete footings with a 10" shaft diameter and 42" total depth (cylindrical straight shaft) requires 1.91 cu.ft net volume per pier. Including a 10% earth-auger and spillage allowance yields 16.80 cu.ft (0.62 cubic yards) total concrete.

Order 28 bags of 80-lb pre-blended concrete (0.60 cu.ft/bag), 38 bags of 60-lb mix (0.45 cu.ft/bag), or 45 bags of 50-lb mix, hydrated with approximately 21 gallons of clean water. Resting on 2,000 PSF soil per 2024 IRC Table R401.4.1, each pier's 0.55 sq.ft footprint supports up to 1,091 lbs.

Tube Diameter Volume & Soil Bearing Comparison (8 Piers @ 42" Depth)

Tube Size Net / Pier Gross Total (+10%) 80-Lb Bags 60-Lb Bags Soil Bearing / Pier
8" Tube 1.22 ft³ 10.75 ft³ 18 Bags 24 Bags 698 lbs
10" Tube (Selected) 1.91 ft³ 16.80 ft³ 28 Bags 38 Bags 1,091 lbs
12" Tube 2.75 ft³ 24.19 ft³ 41 Bags 54 Bags 1,571 lbs
16" Tube 4.89 ft³ 43.00 ft³ 72 Bags 96 Bags 2,793 lbs
20" Tube 7.64 ft³ 67.20 ft³ 112 Bags 150 Bags 4,363 lbs

Pier Excavation, Rebar Cage & Pour Lift Schedule (42" Total Pier Height)

Elevation Zone Target Dimension ACI 318 / IRC R403 Field Requirement
1. Subgrade Base 36" Below Grade 6"+ below local frost depth on undisturbed native soil
2. Rebar Clear Cover 3" Bottom / 2" Side Suspend #4 vertical bars on plastic chairs (never driven into dirt)
3. Above-Grade Plinth +6" Splash Reveal Wet-set 1/2" or 5/8" HDG J-bolt w/ 7" embedment for Simpson ABU base

Official Building Code & Industry Standard Citations

  • ICC International Residential Code (IRC R403.1) Sets minimum footing sizes by load and presumptive soil bearing capacity, and requires footings to bear below the local frost line. Reference: ICC Digital Codes (codes.iccsafe.org).

Field Manuals & Code Tables for Sonotube Footing Calculator

Index of All 107 Manuals →

Frequently Asked Questions (10" × 42" Frost Pier (8x))

How many 80-lb and 60-lb bags of concrete do 8 piers of 10" × 42" require?

▼

Each 10" × 42" cylindrical pier holds 1.91 cu.ft net. For 8 piers with 10% waste (16.80 cu.ft / 0.62 cu.yd), purchase 28 bags of 80-lb mix (or 38 bags of 60-lb mix) and ~21 gallons of clean water.

How much vertical load can one 10" Sonotube footing support at 2000 PSF?

▼

With a bottom bearing footprint of 0.55 sq.ft resting on undisturbed 2,000 PSF soil per IRC Table R401.4.1, each pier supports up to 1,091 lbs of allowable tributary dead-plus-live load.

Should I mix bagged concrete or order a ready-mix truck for 16.8 cu.ft (0.62 yd³)?

▼

At 0.62 cubic yards (28 × 80-lb bags), mixing 4,000 PSI bagged concrete on-site in a 3.5–5.0 cu.ft drum mixer avoids ready-mix short-load delivery fees.