Skip to main content
LAYOUTCALCULATOR SCALE 1/16" CAD
2024 IRC R403 & ACI 318 • SCALE: 1/16" FRACTIONAL
ACI 318 / IRC R403 Pier Concrete & Foundations

18" × 48" Pavilion (6x) — 18" × 48" Sonotube Concrete Yards & Bags (6 Piers)

Heavy-duty 18-inch by 48-inch Sonotube concrete volume for 6 pavilion piers: 7.07 cu ft per pier, 1.73 cubic yards ready-mix, and 5,301 lbs bearing.

Calculation notes
Checked against: 2024 IRC R403 & ACI 318
Published by LayoutCalculator. Confirm with your local building official.
REV DATE:
Result summary

Each 18" × 48" caisson holds 7.07 cu ft net (~12 × 80-lb bags per hole!). Six piers (+10% waste) total 46.65 cu ft (1.73 cu yd / 78 bags), supporting 5,301 lbs per pier on 3,000 psf compact gravel/sand.

Typical Field Application

8x8 timber-frame pavilions, portico columns, structural steel carport posts, and elevated cabin piers.

Field note

At 1.73 cubic yards (3.1 tons of concrete), order 4,000 PSI air-entrained ready-mix concrete (5–7% air content per ACI 318 exposure class F2) rather than hand-mixing 78 bags.

IRC R403.1 & ACI 318 2D SVG Concrete Sonotube & Footing Pier Console
80-lb Bags 78 Bags
Volume 1.73 yd³
Pier Load 5,301 lb
18" Ø Tube
8" (Fence) 12" (Deck) 18" (Porch) 36" (Caisson)
48" (4.0 ft)
18" (South) 42" (36" Frost) 54" (48" Frost) 96"
6 Piers
✓ IRC R403.1 FOOTING BEARING VERIFIED 5,301 lb/pier

Each pier supports 5,301 lbs allowable axial load (31,806 lbs across 6 piers). Batch ≥ 1.50 yd³: order a Ready-Mix Concrete Truck instead of hand-mixing 78 bags!

2D IRC R403.1 Concrete Sonotube Pier, Frost Line, Rebar & Bearing Blueprint Interactive scale CAD cross-section of a cylindrical concrete Sonotube pier showing grade horizon, winter frost line, 6-inch above-grade projection, #4 rebar cage, ABU66Z post standoff base, and soil bearing capacity. FINISH GRADE HORIZON (0.0") WINTER FROST DEPTH LINE (-42") ABU66Z POST BASE + 1/2" J-BOLT (+6" DRY) ↑ ↑ ↑ ALLOWABLE BEARING: 5,301 LBS/PIER @ 3,000 PSF ↑ ↑ ↑ Total: 48" 6 PIERS (18" Ø) | 80-LB BAGS: 78 (1.73 YD³) Single Pier: 7.07 ft³ • Gross w/ 10% Waste: 46.7 ft³
80-lb Mix Bags
78 Bags
Add ~58.5 gal Water
60-lb / 50-lb
104 / 125
60lb / 50lb Bags
Cubic Yards
1.73 yd³
46.7 ft³ Gross
Per-Pier Volume
7.07 ft³
11.8 × 80lb / pier
Max Pier Load
5,301 lb
1.77 ft² Footprint

Concrete Volume, Bag Yield & Bearing Table Ready-Mix Truck Rec.

Calculated per ASTM C387 / Quikrete commercial bag yields (0.60 ft³ per 80-lb bag) and 2024 IRC Table R401.4.1 soil bearing values:

Concrete Sonotube Volume, Bag Counts, Water Ratio, and Soil Bearing Schedule
Engineering Metric Calculated Quantity Jobsite Mix / Code Spec
Single Pier Net Volume 7.07 cu ft 0.262 cu yd net
Gross Batch (+10% Waste) 46.65 cu ft 1.73 cubic yards (6 piers)
80-lb Concrete Bags (0.60 ft³) 78 Bags 1.9 pallets • 58.5 gal mix water
60-lb Concrete Bags (0.45 ft³) 104 Bags 6,240 lbs total dry weight
50-lb Fast-Setting Bags (0.375 ft³) 125 Bags Rapid post/light pier option
Allowable Axial Load / Pier 5,301 lbs 1.77 sq ft @ 3,000 PSF

Required Bill of Materials (BOM) & Hardware

Auto-Calculated Quantities
  • 78 × 80-lb Bags 4,000 PSI Air-Entrained Concrete Mix (or 104 × 60-lb) 1.73 yd³ gross batch including +10% excavation waste
  • 6 × 18" Ø Wax-Lined Cardboard Concrete Pier Forms Cut to 48" height per pier (+6" above finish grade)
  • 6 × Simpson Strong-Tie ABU66Z Standoff Post Bases & 1/2"×8" HDG J-Bolts Plus 12 × #4 (1/2") Deformed Steel Rebar Dowels (maintain 3" bottom concrete cover)

Independent Field Spec Notice: Footing volumes, soil capacities, and 3-inch earth-cast rebar cover follow 2024 IRC R403.1, Table R401.4.1, and ACI 318. Confirm local winter frost depth with your municipal building department.

Need full-scale Pier Excavation & Batch Sheet + Vector .SVG file?

Pre-Calculated Sonotube Footing Calculator Blueprints (12 Field Specs)

Select any standard jobsite specification below to load its exact 2D SVG diagram and engineering tables:

Open Base Sonotube Footing Calculator →
Contractor & Instructor Widget

Embed This 2D SVG Instrument on Your Website (Ad-Free)

Carpentry instructors, trade schools, and builders can embed the standalone ad-free version of this 2D CAD calculator with one HTML snippet.

SPECIFICATION WALKTHROUGH // 18" × 48" Pavilion (6x)

Mathematical Derivation & Field Specifications: 18" × 48" Pavilion (6x)

Updated • Published by LayoutCalculator

Pouring 6 concrete footings with a 18" shaft diameter and 48" total depth (cylindrical straight shaft) requires 7.07 cu.ft net volume per pier. Including a 10% earth-auger and spillage allowance yields 46.65 cu.ft (1.73 cubic yards) total concrete.

Order 78 bags of 80-lb pre-blended concrete (0.60 cu.ft/bag), 104 bags of 60-lb mix (0.45 cu.ft/bag), or 125 bags of 50-lb mix, hydrated with approximately 58.5 gallons of clean water. Resting on 3,000 PSF soil per 2024 IRC Table R401.4.1, each pier's 1.77 sq.ft footprint supports up to 5,301 lbs.

Tube Diameter Volume & Soil Bearing Comparison (6 Piers @ 48" Depth)

Tube Size Net / Pier Gross Total (+10%) 80-Lb Bags 60-Lb Bags Soil Bearing / Pier
8" Tube 1.40 ft³ 9.22 ft³ 16 Bags 21 Bags 1,047 lbs
10" Tube 2.18 ft³ 14.40 ft³ 24 Bags 32 Bags 1,636 lbs
12" Tube 3.14 ft³ 20.73 ft³ 35 Bags 47 Bags 2,356 lbs
16" Tube 5.59 ft³ 36.86 ft³ 62 Bags 82 Bags 4,189 lbs
20" Tube 8.73 ft³ 57.60 ft³ 96 Bags 128 Bags 6,545 lbs

Pier Excavation, Rebar Cage & Pour Lift Schedule (48" Total Pier Height)

Elevation Zone Target Dimension ACI 318 / IRC R403 Field Requirement
1. Subgrade Base 42" Below Grade 6"+ below local frost depth on undisturbed native soil
2. Rebar Clear Cover 3" Bottom / 2" Side Suspend #4 vertical bars on plastic chairs (never driven into dirt)
3. Above-Grade Plinth +6" Splash Reveal Wet-set 1/2" or 5/8" HDG J-bolt w/ 7" embedment for Simpson ABU base

Official Building Code & Industry Standard Citations

  • ICC International Residential Code (IRC R403.1) Sets minimum footing sizes by load and presumptive soil bearing capacity, and requires footings to bear below the local frost line. Reference: ICC Digital Codes (codes.iccsafe.org).

Field Manuals & Code Tables for Sonotube Footing Calculator

Index of All 107 Manuals →

Frequently Asked Questions (18" × 48" Pavilion (6x))

How many 80-lb and 60-lb bags of concrete do 6 piers of 18" × 48" require?

▼

Each 18" × 48" cylindrical pier holds 7.07 cu.ft net. For 6 piers with 10% waste (46.65 cu.ft / 1.73 cu.yd), purchase 78 bags of 80-lb mix (or 104 bags of 60-lb mix) and ~58.5 gallons of clean water.

How much vertical load can one 18" Sonotube footing support at 3000 PSF?

▼

With a bottom bearing footprint of 1.77 sq.ft resting on undisturbed 3,000 PSF soil per IRC Table R401.4.1, each pier supports up to 5,301 lbs of allowable tributary dead-plus-live load.

Should I mix bagged concrete or order a ready-mix truck for 46.7 cu.ft (1.73 yd³)?

▼

At 1.73 cubic yards (78 × 80-lb bags), ordering short-load or metered 4,000 PSI ready-mix concrete saves mixing 6.2 tons by hand and ensures monolithic cold-joint-free pours.