Skip to main content
LAYOUTCALCULATOR SCALE 1/16" CAD
2024 IRC Section R802 • SCALE: 1/16" FRACTIONAL
IRC R802 Birdsmouth Check Framing & Carpentry

24-Ft Gable (6/12 Pitch) — 24-Ft Roof Rafter Layout: 6/12 Pitch & Birdsmouth

2D SVG rafter blueprint for a 24-ft building span at 6/12 roof pitch: 13 ft 4-3/16 in line length, 26.6° plumb cut, 16" overhang, and 2x8 lumber list.

Calculation notes
Checked against: 2024 IRC Section R802
Published by LayoutCalculator. Confirm with your local building official.
REV DATE:
Result summary

Deducting half of a 1-1/2" ridge board leaves a 143-1/4" adjusted run. At 6/12 pitch (26.6°), line length is 160-3/16" plus a 17-7/8" tail (14 ft 10-1/16 in total—buy 16-ft 2x8 stock).

Typical Field Application

Standard two-car detached garages, single-story ranch homes, and backyard workshops in moderate snow zones.

Field note

Cut and dry-fit one pair of pattern rafters with a 1-1/2" scrap block between the ridge plumb cuts to verify tight seat bearing before gang-cutting the roof.

IRC R802.4 & R802.7 2D SVG Roof Rafter & Birdsmouth Drafting Console
Line Len 13' 4-3/16"
HAP 6-3/8"
IRC R802 PASS (6/12)
24' (288")
8' (Shed) 16' (1-Car) 24' (2-Car) 48' (Barn)
6/12 (26.6°)
3/12 (Low) 6/12 (Ranch) 9/12 (Steep) 12/12 (45°)
16" Horiz
✓ PASSES 2024 IRC R802.7.1 NOTCH LIMIT 26.6° Plumb

3-1/2" full plate bearing produces a 1-9/16" perpendicular notch (≤ 2-7/16" max D/3 limit for 2x8). HAP is 6-3/8".

2D IRC R802 Roof Rafter Span, Rise, Line Length & Birdsmouth HAP Blueprint Interactive scale CAD drawing of a gable roof framing cross-section showing exterior walls, ridge board deduction, common rafter line length, soffit tail, collar tie zone, and birdsmouth Height Above Plate. COLLAR TIE (UPPER 1/3) Rise: 5' 11-5/8" Net Run: 11' 11-1/4" Building Span: 24' 0" (288") + 16" Soffits PITCH: 6/12 (26.6°) | LINE: 13' 4-3/16" Total Cut w/ Tail: 14' 10-1/16" • HAP: 6-3/8"
Rafter Line Len
13' 4-3/16"
Run: 143-1/4"
Total Cut + Tail
14' 10-1/16"
Buy 16-ft 2x8
Height Above Plate
6-3/8"
Heel Cut: 1-3/4"
Plumb / Seat Angle
26.6° / 63.4°
Rise: 5' 11-5/8"
Total Rafters
50 pcs
25/side @ 16" OC

Hooked Tape-Measure Rafter Layout Schedule 13.42" / ft Run

Cut the ridge plumb angle at the top tip (0"), hook your tape on the long point of the crown edge, and pull down the board:

Cumulative Hooked Tape-Measure Marks Along Roof Rafter Top Edge
Layout Station Cumulative Mark Shop Saw / Square Spec
1. Ridge Plumb Cut (Peak) 0" (Hook Board Tip) 26.6° Miter Angle
2. Collar Tie Zone (Upper 1/3) 53-3/8" (53.39") IRC R802.4.6 Strap Limit
3. Birdsmouth Heel Plumb Line 160-3/16" (13' 4-3/16") HAP: 6-3/8"
4. Birdsmouth Level Seat Cut 3-1/2" Level Bearing 63.4° Seat • 1-3/4" Heel
5. Fascia Soffit Tail Plumb Cut 178-1/16" (14' 10-1/16") Tail: +17-7/8"

Required Bill of Materials (BOM) & Hardware

Auto-Calculated Quantities
  • 50 × 16-ft 2x8 #2 Kiln-Dried Framing Rafters 25 rafters per slope @ 16" OC across 32-ft ridge
  • 33 Sheets × 4x8 (7/16" or 5/8") APA Structural Roof Sheathing Covers 950 sq ft sloped roof deck (+10% gable/starter waste)
  • 50 × Simpson Strong-Tie H2.5A Hurricane Rafter Ties Plus 9 × 1x6/2x4 Collar Ties (4ft OC) & 2 × 16-ft Ridge Boards

Independent Field Spec Notice: Geometry and birdsmouth notch limits follow 2024 IRC Sections R802.4, R802.6, and R802.7.1. Verify snow-load lumber spans against local R802.4.1 tables.

Need full-scale Jobsite Cut Sheet + Vector .SVG blueprint?

Pre-Calculated Roof Rafter Calculator Blueprints (12 Field Specs)

Select any standard jobsite specification below to load its exact 2D SVG diagram and engineering tables:

Open Base Roof Rafter Calculator →
Contractor & Instructor Widget

Embed This 2D SVG Instrument on Your Website (Ad-Free)

Carpentry instructors, trade schools, and builders can embed the standalone ad-free version of this 2D CAD calculator with one HTML snippet.

SPECIFICATION WALKTHROUGH // 24-Ft Gable (6/12 Pitch)

Mathematical Derivation & Field Specifications: 24-Ft Gable (6/12 Pitch)

Updated • Published by LayoutCalculator

For a 24-foot (288") building width framed at a 6/12 roof pitch (26.6° slope) with a 1.5" ridge board, subtracting half the ridge thickness per side leaves an adjusted horizontal run of 143-1/4" (143.25"). Multiplying by the unit secant factor 1.1180 establishes a ridge-to-heel line length of 13' 4-3/16" (160.16") and a ridge peak rise of 71.6" (5.97 ft) above the wall plate.

Adding a 16" horizontal eave projection contributes 17-7/8" of sloped tail stock, bringing overall cut length to 14' 10-1/16" (order 16-ft 2x8 boards). Per 2024 IRC Section R802.7.1, birdsmouth end notches on 2x8 (7.25" actual depth) must not exceed 2-7/16" (D/3), preserving a 6-3/8" Height Above Plate (HAP) across all 56 rafters (25 pairs @ 16" OC + 10% cull).

Roof Pitch Sensitivity Matrix for 24-Ft Building Span (16" Overhang)

Roof Pitch Plumb Cut Angle Secant Factor Main Line Length Total w/ Overhang Min Lumber Stock
4/12 18.4° 1.0541 12' 7" 13' 11-7/8" 14 ft 2x8
6/12 (Selected) 26.6° 1.1180 13' 4-3/16" 14' 10-1/16" 16 ft 2x8
8/12 33.7° 1.2019 14' 4-3/16" 15' 11-3/8" 16 ft 2x8
10/12 39.8° 1.3017 15' 6-1/2" 17' 3-5/16" 18 ft 2x8
12/12 45.0° 1.4142 16' 10-9/16" 18' 9-3/16" 20 ft 2x8

Pattern Rafter Scribe & Saw Layout Checkpoints (2x8 @ 6/12)

Checkpoint Hooked Tape / Angle Code / Framing Rule
1. Ridge Plumb Cut 0" Origin • 26.6° Miter Crown edge facing UP; deduct 0.75" half-ridge
2. Birdsmouth Heel Plumb 13' 4-3/16" (160.16") HAP = 6-3/8" above top plate; 3-1/2" level seat
3. Fascia Tail Plumb Cut 14' 10-1/16" (178.05") 16" horizontal soffit projection (26.6° plumb)

Official Building Code & Industry Standard Citations

Field Manuals & Code Tables for Roof Rafter Calculator

Index of All 107 Manuals →

Frequently Asked Questions (24-Ft Gable (6/12 Pitch))

What is the exact rafter line length and plumb cut angle for a 24-ft span at 6/12 pitch?

▼

Deducting half of a 1.5" ridge board from a 24-ft (288") building width leaves an adjusted horizontal run of 143-1/4". At 6/12 pitch (26.6° plumb cut, 63.4° seat cut), ridge-to-heel line length is 13' 4-3/16" (160.16") plus a 17-7/8" overhang tail (14' 10-1/16" overall).

What is the maximum birdsmouth notch depth allowed by IRC R802.7.1 on 2x8 rafters?

▼

Under 2024 IRC Section R802.7.1, an end-bearing birdsmouth notch cannot exceed one-third (D/3) of the actual rafter depth. For 2x8 lumber (7.25" actual depth), maximum notch depth is 2-7/16", preserving a 6-3/8" Height Above Plate (HAP).

What lumber length and quantity should I order for a 24' × 32' gable roof at 16" OC?

▼

Each 14' 10-1/16" common rafter requires 16-foot 2x8 stock. Across a 32-foot roof ridge at 16" on-center (25 rafter pairs), order 56 boards including a 10% culling buffer.